Technical Data

Twin Compact Series Technical Specifications

Model Range Standard Standard Standard High Temperature High Temperature Hybrid Hybrid Three Phase Three Phase Three Phase
Phase Single Single Single Single Single Single Single Three Three Three
Nominal thermal kW rating at B0/W35 16 20 24 12 17 15 21 20 24 30
Nominal thermal kW rating at B0/W60 11.3 15.3
Nominal thermal kW rating at B0/W65 11 15
Part Number C160-T1H C200-T1H C240-T1H H124-T1H H170-T1H M150-T1H M210-T1H C200-T3H C240-T3H C300-T3H
MCS Approved BBA0055/07 BBA0055/08 BBA0055/09 BBA0055/28 BBA0055/29 BBA0055/32 BBA0055/33 BBA0055/13 BBA0055/14 BBA0055/15
Performance data - rated heating output at B0/W35 BS EN14511
Power consumption 5.2 5.8 7.2 5.79 7.23 3.9 5.3 5.7 6.9 8.1
Co-efficient of Performance at B0/W35 4.15 4.16 4.14 4.16 4.15 4.15 4.14 4.15 4.18 4.15
Co-efficient of Performance at B0/W65 2.08 2.1 2.31 2.39 2.3
Immersion heater output Kensa heat pumps do not feature back-up electric immersion heaters
Brine (primary): Based on 0?C in / -4?C
Design flow rate kg/min 52.7 61.2 75.4 39 43.9 47.16 70.14 61.5 76.2 91.6
Pressure drop kPa at design flow rate 11.2 15.3 22.2 6.79 12.6 12.8 22.7 15.4 22.6 31.5
Max inlet temperature ?C 15 15 15 20 20 15 15 15 15 15
Min temperature ?C (outlet) -5 (at standard settings) -5 (at standard settings) -5 (at standard settings) -5 (at standard settings) -5 (at standard settings) -5 (at standard settings) -5 (at standard settings) -5 (at standard settings) -5 (at standard settings) -5 (at standard settings)
Heating water (secondary): Based on 30?C in / 35?C out
Design flow rate l/min 50.6 58.4 72 40.2 48.8 44.03 61.86 58.2 71.8 85.9
Pressure drop kPa at design flow rate 9.3 12.3 18.7 5.94 8.71 7.1 13.9 12.3 18.6 26.5
Max flow temperature ?C*** 55 55 55 65 65 65 65 55 55 55
Electrical values at B0/W35
Rated voltage 220 - 240V / 50Hz 220 - 240V / 50Hz 220 - 240V / 50Hz 220 - 240V / 50Hz 220 - 240V / 50Hz 220 - 240V / 50Hz 220 - 240V / 50Hz 400 V / 50 - 60 Hz 400 V / 50 - 60 Hz 400 V / 50 - 60 Hz
Power supply rating amps 63 63 63 50 50 50 60 25 32 32
Rated current (max) amps 43.7 52.5 65.4 42.9 48 43 58 18.9 23.6 27
Typical running current at B0/W35 amps 27.4 28 35.4 26.9 27.9 25 29 12.2 15.2 17.5
Starting current amps **** 44 44 48 42 42 44 48 55 68 79
Refrigerant circuit
Process medium R407C R407C R407C R134a R134a R407c/R134a R407c/R134a R407C R407C R407C
Fill volume kg 2.2 2.4 2.6 2 2.6 1.0 / 1.4 1.3 / 1.4 2.4 2.6 2.4
Compressor type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
Dimensions
H X W X L (mm) 900 x 900 x 570 900 x 900 x 570 900 x 900 x 570 900 x 900 x 570 900 x 900 x 570 900 x 900 x 570 900 x 900 x 570 900 x 900 x 570 900 x 900 x 570 900 x 900 x 570
Dry weight kg 167 170 180 165 167 167 180 170 180 185
Operating pressure
Brine circuit min (primary) bar g 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Heating water circuit min (secondary) bar g 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Low pressure reset bar g 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8
Connection sizes
Primary IN and OUT (speedfit) mm 50 50 50 28 50 50 50 50 50 50
Heating flow and return (speedfit) mm 28 28 28 28 50 28 28 28 28 28
Performance (based on Average Climate) @ 35?C
ErP rating A++ A+ A+ A++ A++ A++ A+ A++ A+ A+
SCOP***** 3.99 3.82 3.87 3.98 4.03 4.14 3.93 4.15 3.83 3.69
Seasonal space heating energy efficiency 152% 145% 147% 151% 153% 158% 149% 158% 145% 140%
Performance (based on Average Climate) @ 55?C
ErP rating A+ A+ A+ A+ A+ A+ A+ A+ A+ A+
SCOP***** 3.18 3.14 2.94 3.14 3.27 3.25 3.13 3.3 3.13 3.11
Seasonal space heating energy efficiency 119% 118% 110% 118% 123% 122% 117% 124% 117% 116%
Sound Power Level
Sound Power Level (dB) 58 59 61 64 60 66 63 59 59 59

* The COP figure quoted is calculated as per EN14511

** In-built immersion heaters will increase running costs and CO2 emissions as they use direct electricity, because of this Kensa heat pumps do not include them.

*** By increasing the flow temperature from the heat pump the efficiency of the unit will drop and the COP decreases.

**** Kensa single pumps heat pumps incorporate smart starts as standard to limit the starting current of the compressors. For full details on how the starting currents are calculated please contact Kensa.

Note: Design flow rates are for a ground temperature of 0°C and –4°C and a load temperature of 30°C and 35°C.